Lachat quikchem 8500 manual






















The bench space required for a QuikChem® FIA System with up to five channels, dilutor, sampler, computer and printer is: • Width: m (9 ft) • Depth: m ( ft) • Height: m (2 ft) Figure 1 QuikChem FIA overview 1 Autosampler 5 Computer and peripherals 2 Dilutor (in rear) 6 Power cords 3 Pump 7 Communication cables 4 System unit. Section 5 Maintenance DANGER Only qualified personnel should conduct the tasks described in this section of the manual. Preventive maintenance is extremely important for long-term operation. The following tips ® will help keep the QuikChem Series 2 operation at maximum potential. Keep all modules clean and dry at all times.  · Lachat’s Quikchem® Series 2 Flow Injection Analysis System features high sample throughput and simple, rapid method changeover. The Quikchem Flow Injection Analysis system maximizes productivity in determining ionic species in a variety of sample types, from sub-ppb to Accuracy and Reproducibilit: %.


ID: Lachat TN Revision: 1 August Page 3 of 18 1 Identification of the method Operation of the ®QuikChem Flow Injection Analysis System. 2 Applicable matrix or matrices This instrument can be used for natural water, sediment, and biomass samples. 3 Detection Limit The applicable range is to mg/L. Written and copyrighted by L. Egan on 21 February by Lachat Instruments, Lindbergh Drive, Loveland, CO USA. Phone: FAX: This document is the property of Lachat Instruments. Unauthorized copying of this document is prohibited. QuikChem® Method I Ammonia (Phenolate) in Brackish or Seawater. Yes. If you own a QuikChem IV system we will give a credit allowance, depending on the age of the system and the number of channels. XYZ samplers and pumps on the QuikChem AE, QuikChem , and QuikChem systems can be upgraded to be used on the new QuikChem Series 2 system. Omnion can also be upgraded as part of the new system.


Lachat’s Quikchem® Series 2 Flow Injection Analysis System features high sample throughput and simple, rapid method changeover. The Quikchem Flow Injection Analysis system maximizes productivity in determining ionic species in a variety of sample types, from sub-ppb to percent concentrations. The QuikChem Series 2 system maximizes productivity in determining ionic species in a variety of sample types—from sub-ppb to percent concentrations. More than methods are available for environmental, agronomic and industrial applications- including EPA-accepted methods. Lachat QuickChem Series 2 Flow Injection Analysis System – Inorganic Nitrogen. Active In use from Abstract. The Lachat QuickChem Series 2 Flow Injection Analysis System is a flow injection colorimetric analyzer used for the analysis of inorganic N and phosphate in soil extracts and water samples.

0コメント

  • 1000 / 1000