Dupline gtu 8 manual
CARLO GAVAZZI GTU-8 DUPLINE Fieldbus Network Tester Line Monitor Test Unit M3RTM Note: New in original factory packaging. Box is scuffed from storage. Leather case is NOT standard supply, but is INCLUDED as well as the cable. See photos. You will receive 1 x Test unit GTU8 1 x Leather case 1 x Cable DFTU8CAB Features Portable test unit Missing: manual. GTU 8 är en portabel sändare/mottagare för kanaler, strömförsörjd via Dupline. Enheten rekommenderas vid idrifttagning samt för kontroll av Dupline-installationer. GTU 8 har fyra olika funktioner: Digital 1 group Digital 2 groups Edit Tx-latch Analog BCD GTU 8 startar med ”Digital 1 group” Ändring av funktion: 1. Tryck ”Mode” 2. How to define the number of Dupline® networks 29 Dupline® bus in the cabinet 31 The wireless bus WiDup 34 How to connect the Mobile modem 34 How to connect the USB Dongle Connection Module SH2DSP24 35 Ethernet connection 37 Micro SD 38 USB stick installation
SMS Control commands and Requests for Dupline data 92 6. Radio Modem Functions 93 General 93 Setup of Radio Modem Central 94 Setup of Radio Modem Substation 95 Appendix A 96 Appendix B - ModBus Functions 97 Appendix C - RS Communications operation for the Dupline - Safe Configuration and test unit: www.doorway.ruurationmodeand www.doorway.ruitmode. In Configuration mode the unit can set up the Dupline - Safe Safety Relay Output module or the Safety Input module. In Test Unit mode the unit can monitor the Safety units ontheDuplineSafebus. Activation of the Con-figuration and Test Unit for. Buy GTU8 - Carlo Gavazzi - DUPLINE HAND HELD TEST UNIT. Newark offers fast quotes, same day shipping, fast delivery, wide inventory, datasheets technical support.
GTU mode: When connecting to the Dupline ® bus through the Jack plug, GTU mode is enabled. This is done by pressing the “Read / On” button on the Configura - tor when the Dupline ® bus is connect - ed. Then the display will show the standardGTU“Mode1”. GTUmode1 Fi g TheGTUhave4modes. - Mode1-Abletoseeone Dupline ® group - Mode2. GTU Test Tool: These tools are used to display the immediate digital status on the Dupline channels. When enabled, control of the Dupline channels is possible as well. This tool provides a good overview of the activity on the Dupline bus and is particularly good when testing the application. Generator firmware. Dupline® is a registered trademark. A product of the CARLO GAVAZZI Group Output Dupline® Connection 3 mm Jack socket Display 2 x 16 characters Type LCD Height of dots 5 mm Keyboard Tactile keys No. of keys 12 Channel keys Command keys «↑» «↓» (scroll up/down) «MODE», «ENTER» Cable 1 GTU8 to Dupline® GTU8 connector 3.
0コメント